ОП “Електромеханічні системи автоматизації, електропривод та електромобільність”, факультет електроенерготехніки та автоматики "КПІ ім. Ігоря Сікорського"

Suppression of line voltage related distortion in current controlled grid connected inverters

Suppression of line voltage related distortion in current controlled grid connected inverters

Suppression of line voltage related distortion in current controlled grid connected inverters (2005) IEEE Transactions on Power Electronics
Abeyasekera, T., Johnson, C.M., Atkinson, D.J., Armstrong, M.

The influence of selected control strategies on the level of low-order current harmonic distortion generated by an inverter connected to a distorted grid is investigated through a combination of theoretical and experimental studies. A detailed theoretical analysis, based on the concept of harmonic impedance, establishes the suitability of inductor current feedback versus output current feedback with respect to inverter power quality. Experimental results, obtained from a purpose-built 500-W, three-level, half-bridge inverter with an L-C-L output filter, verify the efficacy of inductor current as the feedback variable, yielding an output current total harmonic distortion (THD) some 29% lower than that achieved using output current feedback. A feed-forward grid voltage disturbance rejection scheme is proposed as a means to further reduce the level of low-order current harmonic distortion. Results obtained from an inverter with inductor current feedback and optimized feed-forward disturbance rejection show a THD of just 3% at full-load, representing an improvement of some 53% on the same inverter with output current feedback and no feed-forward compensation. Significant improvements in THD were also achieved across the entire load range. It is concluded that the use of inductor current feedback and feed-forward voltage disturbance rejection represent cost-effect mechanisms for achieving improved output current quality.

Abeyasekera, T., Johnson, C.M., Atkinson, D.J., Armstrong, M. Suppression of line voltage related distortion in current controlled grid connected inverters (2005) IEEE Transactions on Power Electronics, 20 (6), pp. 1393-1401.

Статистика



За результатами 1 семестру

2022/2023 навчального року


Всього навчається: 137,
з них на бюджеті: 130.

Оголошення



Освітній процес у 2 семестрі 2022/23 н.р. згідно рекомендацій МОН розпочнеться з 6 лютого 2023 року в ДИСТАНЦІЙНОМУ режимі.


Останні оголошення

Партнери

Центр міжнародної освіти